MI:DBA-CS2A:4G15:F1C1A:OGW:ENG:stall:AC:効きが悪い:LANCER:HDM3K:THW:119℃:保証延長:
057524km

WN15No1625B


1) エアコンの効きが悪い

2) 停車直前、突然エンスト、しばらくして再始動


3) cooling fan作動不安定、ACと共用で motor 1つタイプ

4) HDM3K:THW:119℃:水温計振り切れ







保証延長:
http://www.mitsubishi-motors.co.jp/support/recall/others/detail/02.html

2008 mitsubishi lancer. heater blower motor shelled a bearing. replaced motor. new motor will not run. tested with battery. motor good. pulled blower motor resistor. checked it
out. junk. replaced resistor. motor still won't run. checked for current to resistor. no current.
all fuses good. all relays good. what's the problem?


http://www.justanswer.com/mitsubishi/7mjw1-mitsubushi-lancer-2008-mitsubishi-lancer-heater-blower.html

閉じる コメント(33)

顔アイコン

エアコンの故障診断
web.kyoto-inet.or.jp/people/macchann/hiroshi/compressor-2.html
コンデンサー部の腐食の写真). 漏れ止め剤を 入れてから しばらく効いていたが、徐々に エアコンが 効きにくくなった (あるいは 効かなくなった) ... エアコンがONするとエンストしやすい, ○エアコンのアイドルアップ装置が作動していない、 コンプレッサーの回転 ...

2015/8/11(火) 午前 8:14 [ ogw*og*3 ]

顔アイコン

mitsubushi lancer: have a 2008 mitsubishi lancer. heater blower
Customer Question
have a 2008 mitsubishi lancer. heater blower motor shelled a bearing. replaced motor. new motor will not run. tested with battery. motor good. pulled blower motor resistor. checked it
out.

http://www.justanswer.com/mitsubishi/7mjw1-mitsubushi-lancer-2008-mitsubishi-lancer-heater-blower.html

2016/3/9(水) 午後 6:59 [ ogw*og*3 ]

顔アイコン

junk. replaced resistor. motor still won't run. checked for current to resistor. no current.
all fuses good. all relays good. what's the problem?

2016/3/9(水) 午後 7:00 [ ogw*og*3 ]

顔アイコン

三菱ランサーは:2008三菱ランサーを持っています。ヒーターブロワーは、お客様の質問には、2008年三菱ランサーを持っています。ヒーターブロアモーターはベアリングを砲撃しました。モーターを取り替えました。新しいモーターは動作しません。バッテリーでテスト。モータ良いです。ブロワーモーター抵抗を引っ張りました。それを確認しました でる。 ジャンク。レジスタを取り替えました。モーターはまだ実行されません。抵抗に電流を確認しました。電流ません。すべてが良いヒューズ。すべてが良いリレー。 何が問題なの?

2016/3/9(水) 午後 7:07 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
Hello and welcome to Just Answer!

My name is XXXXX XXXXX I can assist you with your question.

The blower motor resistor will not have current because it is on the ground side circuit of the blower motor.

You need to remove the blower motor relay and check for two powers going into the relay terminals with the key on and blower motor on high.

Please do that for me so we can continue.
Ask Your Own Mitsubishi Question

2016/3/9(水) 午後 7:14 [ ogw*og*3 ]

顔アイコン

Customer: replied 2 years ago.


i have done that. i have 2 powers going into relay terminals

2016/3/9(水) 午後 7:16 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
David,

Excellent! Thank you very much! If you insert the relay, do you hear it click if you were to turn on the heater? If so, do you have power leaving the ETACS ECU going to the blower motor?
Ask Your Own Mitsubishi Question

2016/3/9(水) 午後 7:19 [ ogw*og*3 ]

顔アイコン

Customer: replied 2 years ago.


have read else where to chk for click by having heater blower switch on high w/ key on


and w/ relay pulled out just touch to terminals and feel click. i never felt any click. my daughter said she took to dealer and they said relay was ok. i don't know what a etacs ecu is.

2016/3/9(水) 午後 7:20 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
David,

Thank you very much for the relay!

Let me gather you some information and reply back shortly.

Thank you

2016/3/9(水) 午後 7:22 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
David,

I have been looking through these wiring diagrams and there is more information I will need to get my hands on in order to help you.

2016/3/9(水) 午後 7:23 [ ogw*og*3 ]

顔アイコン

We can do this one of two ways. We can wait until tomorrow until I get this information and I can reply back then or I can leave this question open for other experts as you may be able to get an answer from another expert tonight. Either way it is up to you. I would like to continue to help you. But if you want an answer right away, I understand.

Amedee

2016/3/9(水) 午後 7:24 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
Thank you very much Dave. I will reply back in the morning.

No need to reply back tonight otherwise it will lock this question to me.

I will do some research for you and post a reply in the morning.

Thanks. Have a great night.

2016/3/9(水) 午後 7:28 [ ogw*og*3 ]

顔アイコン

Expert: Amedee replied 2 years ago.
David,

Sorry for the delay! I did some research for you and got some really good information.

This ETACS-ECU is a fuse/relay box with combined with a module (computer). This unit grounds the Blower motor relay to activate it and send power out the yellow wire to the blower motor. If you are sure that this unit is not grounding the blower motor relay, this is (and if all powers and grounds are good) this ETACS-ECU is bad and will need to be replaced.

2016/3/9(水) 午後 7:29 [ ogw*og*3 ]

顔アイコン

However, it may be possible that there is a code in this ETACS-ECU preventing it from activating the relay. The only way to pull codes on this unit with a scanner. You could take it to a shop and have them scan this module for codes. Or, you could disconnect the battery for 10 minutes to clear the memory in this unit. This may just get the blower motor working temporarily.

2016/3/9(水) 午後 7:33 [ ogw*og*3 ]

顔アイコン

If this does the trick, then chances are there was and possibly will be (again) a stored code in the unit causing this condition which in that case it will need to be addressed.

2016/3/9(水) 午後 7:33 [ ogw*og*3 ]

顔アイコン

If this does the trick, then chances are there was and possibly will be (again) a stored code in the unit causing this condition which in that case it will need to be addressed.

2016/3/9(水) 午後 7:34 [ ogw*og*3 ]

顔アイコン

xpert: Amedee replied 2 years ago.
David,

It's Amedee from just answer. I am just checking in to see how things turned out and to see if you need any further assistance. Let me know.

2016/3/9(水) 午後 7:36 [ ogw*og*3 ]

顔アイコン

Customer: replied 2 years ago.


AMEDEE,





thanks for all your help. i haven't had time to takecar to dealer and have codes run.


I'm sure that's what it must be cause current is every where it should be except to the blower motor. thanks again. will let you know what happens.





dave

2016/3/9(水) 午後 7:36 [ ogw*og*3 ]

顔アイコン

BODY DIMENSIONS

http://www.evoscan.com/manuals/EvoX/10_GS41EVO_MMNA_SM/08_GS41EVO_MMNA_BRM_PDF/GR00000900-2.pdf

2016/3/10(木) 午前 7:34 [ ogw*og*3 ]

顔アイコン

2010
MITSUBISHI
LANCER EVOLUTION
SERVICE MANUAL
Volume 2

http://www.evoscan.com/manuals/EvoX/10_GS41EVO_MMNA_SM/GS41E_PrefaceForMMSAVol2.pdf

2016/3/10(木) 午前 8:44 [ ogw*og*3 ]


.


プライバシー -  利用規約 -  メディアステートメント -  ガイドライン -  順守事項 -  ご意見・ご要望 -  ヘルプ・お問い合わせ

Copyright (C) 2019 Yahoo Japan Corporation. All Rights Reserved.

みんなの更新記事